EGAS-54
EGAS-78
Manual high pressure steam sterilizer GAS series
1. External detachable pressure gauge for easy verification.
2. USB as standard.
3. Features.
-The sterilization temperature can be set up to 138 degrees.
-PT1000 sensor is used for more accurate temperature control and display accuracy of 0.1 degrees.
-Configurable negative pressure range -0.1-0.5 pressure gauge, overcurrent and short circuit protection system.
-Standard software and hardware dual dry burning prevention function, overtemperature protection system, overpressure protection safety valve.
-Open the cover to stop heating function.
-After the sterilization is completed, the exhaust valve can be set at the set ten-level exhaust speed.
--Freertos embedded operating system.
-Standard USB flash drive real-time data recording function.
-With F0 value test function.
-Automatic fault monitoring, alarm and recording functions (printer is required), anti-scalding safety protection.
-Automatically detect cold air discharge to ensure pure steam sterilization.
-The boiling point temperature can be set according to the altitude.
-The exhaust temperature can be adjusted within the boiling point temperature plus 0~25 degrees.
-Dual temperature sensors can detect air temperature and water temperature, which is safer to use.
-The tank body has a verification hole reserved for easy verification of the connection.
-Mechanical pressure interlock device cover inspection system.
-Overcurrent protection device.
Beam safety monitoring: The beam position safety monitoring system monitors the beam safety position at all times after the sterilization is started.
Display temperature accuracy: 0.1 degrees.
Inner tank polishing: Inner tank atomization polishing reduces the area of bacterial attachment, prevents dirt residue, and is convenient for users to clean and maintain.
Dry burning protection: Double over-temperature protection, effectively preventing dry burning.
Water temperature sensor: Standard PT1000 water temperature sensor, monitors the surface temperature of the heating tube, and protects against dry burning
Pressure interlocking mechanism.
-Start the machine, sterilize, and start the sterilization process. The micro-position switch monitors the position of the interlocking mechanism in real time. Once there is an abnormality, the machine will automatically alarm and stop to ensure safety.
-The closing state of the locking beam is monitored by the real-time position sensor. After the sterilization is completed, the temperature in the cavity is lower than 95℃, and the opening temperature can be set arbitrarily.
-Double over-temperature protection.
-Double limit protection.
-Heating tube prevents dry burning-with three-layer protection of software and hardware, in addition to protecting dry burning according to the water temperature rising rate, the standard PT1000 water temperature sensor accurately controls the surface temperature of the heating tube to prevent dry burning damage, and the standard liquid expansion over-temperature protection protector generates direct circuit breaker protection for dry burning.
-Fully automatic intelligent control system.
Optional parts (option).
-Printer (print content: pressure in the pot during sterilization, sterilization temperature and time).
-Item sensor.
×